The rangehood that vented into the roof

Warm wet air, delivered to the worst possible place.

Owner Inspections · Pakenham East 3810 · 2026-05-22

In short: An exhaust duct that stops in the roof space is not ducted. It is a humidity problem with a fan attached.

What it should do

Carry cooking moisture and grease out of the building through an external termination.

What we recorded

The duct was absent entirely, with the rangehood discharging directly into the roof cavity above the kitchen.

Why it matters over time

Moist air condenses on the underside of cold roofing, wets insulation and eventually shows as staining or mould on the ceiling below.

Bathroom fans as well

The same finding turns up on extraction fans, where duct connections are made loosely or left disconnected at one end.

Getting it closed out

It is a handover item with a clear remedy, and it is far easier to have done before you sign than after you move in.

Written by the Owner Inspections team from inspections carried out in Pakenham East. Licensed building practitioners, Building & Plumbing Commission registration CDB-U 53425.

Guides

More pci / handover guides for Pakenham East

All guides →

Book a building inspection in Pakenham East

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Pakenham East owners ask about this

Is this allowed anywhere?

Discharge into a roof space is not an acceptable termination for a kitchen or bathroom exhaust. It needs to reach outside air.

How would I spot it?

Put your head in the roof space above the kitchen with the fan running, which is not most owners' idea of a Saturday.

Whose defect is it?

The builder's, as a coordination matter between the cabinetmaker, the roofer and the electrician.

How long does the fix take?

An hour or two for a straightforward run, longer where the roof space is congested with ductwork already.